QUANTUM VP31110W/WD, VP32210W/WD (CAPELLA WIDE SCSI SERIES)
| Interface: |
SCSI-2 F/W/D |
| Size: |
3.5 in. third height |
| View: |
Bottom |

| USER CONFIGURABLE SETTINGS |
| Function |
Location |
Setting |
| Active termination enabled |
J2/jumper 5 |
closed |
| Active termination disabled |
J2/jumper 5 |
open |
| Spindle motor starts on power-up |
J3/jumper 1 |
closed |
| Spindle motor starts on command only |
J3/jumper 1 |
open |
| TRMPWR supplied to SCSI bus |
J4 |
closed |
| TRMPWR is not supplied to SCSI bus |
J4 |
open |
| Drive is first or last drive in chain |
terminators |
installed |
| Drive is not first or last drive in chain |
terminators |
removed |
| DRIVE SELECTION - J2 |
| Drive ID |
Jumper 1 |
Jumper 2 |
Jumper 3 |
Jumper 4 |
| 0 |
open |
open |
open |
open |
| 1 |
closed |
open |
open |
open |
| 2 |
open |
closed |
open |
open |
| 3 |
closed |
closed |
open |
open |
| 4 |
open |
open |
closed |
open |
| 5 |
closed |
open |
closed |
open |
| 6 |
open |
closed |
closed |
open |
| 7 |
closed |
closed |
closed |
open |
| 8 |
open |
open |
open |
closed |
| 9 |
closed |
open |
open |
closed |
| 10 |
open |
closed |
open |
closed |
| 11 |
closed |
closed |
open |
closed |
| 12 |
open |
open |
closed |
closed |
| 13 |
closed |
open |
closed |
closed |
| 14 |
open |
closed |
closed |
closed |
| 15 |
closed |
closed |
closed |
closed |
| USER CONFIGURABLE SETTINGS |
| Function |
Location |
| Remote Busy LED |
J3/pins 11 & 13 |
| Remote Fault LED |
J3/pins 13 & 14 |
| MISCELLANEOUS TECHNICAL NOTES |
a) The wide differential drives ("WD" models) do
not provide active termination.
b) Busy LED & fault LED can also be connected in J2 jumper
block.
c) All other jumpers and their function are unidentified. |
QUANTUM ATLAS XP SERIES: XP31070S, XP32150S, XP34300S
QUANTUM ATLAS II SERIES: XP32181S, XP34361S, XP39100S
| Interface: |
SCSI-2 Fast (ATLAS XP) |
|
SCSI-3 (ATLAS II) |
| Size: |
3.5 in. half height |
| View: |
Bottom |

| DRIVE SELECTION - J3 |
| Drive ID |
Jumper 1 |
Jumper 2 |
Jumper 3 |
| 0 |
open |
open |
open |
| 1 |
closed |
open |
open |
| 2 |
open |
closed |
open |
| 3 |
closed |
closed |
open |
| 4 |
open |
open |
closed |
| 5 |
closed |
open |
closed |
| 6 |
open |
closed |
closed |
| 7 |
closed |
closed |
closed |
| USER CONFIGURABLE SETTINGS |
| Function |
Location |
Setting |
| Active termination enabled |
J4 |
closed |
| Active termination disabled |
J4 |
open |
| TRMPWR supplied to SCSI bus |
J5 |
closed |
| TRMPWR is not supplied to SCSI bus |
J5 |
open |
| Spindle motor starts on power-up with delay of SCSI ID x 12 sec. |
J3/jumper 7 |
closed |
| Spindle motor starts on command only |
J3/jumper 7 |
open |
| Write protect enabled |
J3/jumper 9 |
closed |
| Write protect disabled |
J3/jumper 9 |
open |
| Note: jumpers not mentioned in this document are
unidentified. |
| CONNECTIONS |
| Function |
Location |
| Spindle sync |
J3/pins 10 & 19 |
| Remote busy LED |
J3/pins 11 & 9 |
| Remote fault LED |
J3/pins 11 & 7 |