| Previous | Table of Contents | Next |
CONNER CFS1081A, CFS1621A
| Interface: | EIDE |
| Size: | 3.5 in. third height |
| View: | Bottom |
| DRIVE SELECT | ||
|---|---|---|
| Setting | CD | CS |
Single drive in a system |
closed | open |
| Master drive in a two drive system | closed | open |
| Slave drive in a two drive system | open | open |
| Cable Select is used to determine master/slave | open | closed |
| Note: All other jumpers are factory configured - do not alter. | ||
CONNER CP30540, CP31370
| Interface: | SCSI |
| Size: | 3.5 in. third height |
| View: | Bottom |
| DRIVE SELECTION | |||
|---|---|---|---|
| Drive Number | Jumper E1 | Jumper E2 | Jumper E3 |
| 0 | open | open | open |
| 1 | closed | open | open |
| 2 | open | closed | open |
| 3 | closed | closed | open |
| 4 | open | open | closed |
| 5 | closed | open | closed |
| 6 | open | closed | closed |
| 7 | closed | closed | closed |
| CONNECTIONS | |
|---|---|
| Function | Location |
| External Spindle Sync | J3/jumper 1 |
| Hard drive active LED | J3/jumper 2 |
| Serial I/O connector (for factory use) | J3/jumper 3 - 7 |
| USER CONFIGURABLE SETTINGS | ||
|---|---|---|
| Function | Location | Setting |
Spindle motor starts on power-up |
Jumper E4 | Open |
| Spindle motor starts on command only | Jumper E4 | Closed |
Drive Termination enabled |
Jumper E5 | Closed |
| Drive Termination disabled | Jumper E5 | Open |
TERMPWR supplied by drive to SCSI Interface pin
26 |
Jumper E6 | Closed |
| TERMPWR not present | Jumper E6 | Open |
| MISCELLANEOUS TECHNICAL NOTES |
|---|
| a) OE1, OE2, OE3, OE5, and OE6 perform the same
function as and are mutually exclusive with E1, E2, E3, E5, and E6. b) For model CP30540, on PCBA revisions greater than 09230-003 Y1, OE6 is the LED output signal. For model CP31370, on PCBA revisions greater than 09370-002 Y1, OE6 is the LED output signal. c) SCSI parity is always enabled in both directions. |
FUJITSU M2691EQ/ER, M2692EQ/ER, M2693EQ/ER, M2694EQ/ER
| Interface: | SCSI |
| Size: | 3.5 in. half height |
| View: | Bottom |
| DRIVE SELECTION - CNH11 | ||||
|---|---|---|---|---|
| SCSI ID Number | Jumper 1 | Jumper 2 | Jumper 3 | Jumper 4 |
0 |
open | open | open | open |
| 1 | closed | open | open | open |
| 2 | open | closed | open | open |
| 3 | closed | closed | open | open |
| 4 | open | open | closed | open |
| 5 | closed | open | closed | open |
| 6 | open | closed | closed | open |
| 7 | closed | closed | closed | open |
| 8 | open | open | open | closed |
| 9 | closed | open | open | closed |
| 10 | open | closed | open | closed |
| 11 | closed | closed | open | closed |
| 12 | open | open | closed | closed |
| 13 | closed | open | closed | closed |
| 14 | open | closed | closed | closed |
| 15 | closed | closed | closed | closed |
| USER CONFIGURABLE SETTINGS | ||
|---|---|---|
| Function | Location | Setting |
Factory configured - do not alter |
CNH2/jumper 1 | open |
Factory configured - do not alter |
CNH2/jumper 2 | open |
Factory configured - do not alter |
CNH5 | all open |
Factory configured - do not alter |
CNH10/jumper 1 | N/A |
TERMPWR supplied by drive (ER models
only) |
CNH10/jumper 2 | closed |
| TERMPWR supplied by SCSI pin 26 (ER models only) | CNH10/jumper 2 | open |
TERMPWR is tied to SCSI pin 26 and terminators |
CNH10/jumper 3 | closed |
| TERMPWR is not tied to SCSI pin 26 and terminators | CNH10/jumper 3 | open |
Drive terminators enabled (ER models only) |
CNH10/jumper 4 | closed |
| Drive terminators disabled (ER models only) | CNH10/jumper 4 | open |
Write protect disabled |
CNH11/jumper 5 | closed |
| Write protect enabled | CNH11/jumper 5 | open |
SCSI-2 mode enabled |
SW1/1 | off |
| SCSI mode enabled | SW1/1 | on |
Offline diagnostics enabled |
SW1/2 | off |
| Offline diagnostics disabled | SW1/2 | on |
| USER CONFIGURABLE SETTINGS (CONTINUED) | ||
|---|---|---|
| Function | Location | Setting |
UNIT ATTENTION report mode enabled |
SW1/3 | on |
| UNIT ATTENTION report mode disabled | SW1/3 | off |
Retries are unlimited |
SW1/4 | on |
| Retries are limited to 10 | SW1/4 | off |
SCSI parity check enabled |
SW1/5 | on |
| SCSI parity check disabled | SW1/5 | off |
Synch/Wide mode transfer requests enabled |
SW1/6 | on |
| Synch/Wide mode transfer requestsdisabled | SW1/6 | off |
LED configured to light during activity |
SW1/7 | on |
| LED configured to light when ready | SW1/7 | off |
| TERMINATING POWER CONFIGURATION (M269×EQ MODELS ONLY) - CNH10 | ||
|---|---|---|
| Function | Jumper 2 | Jumper 3 |
TERMPWR connected to SCSI pin 26 and drive
terminators |
closed | closed |
| TERMPWR connected to drive terminators | closed | open |
| TERMPWR connected to SCSI pin 26 and terminators | open | closed |
| SPINDLE MOTOR CONFIGURATION | ||
|---|---|---|
| Setting | CNH11/Jumper 6 | SW1/8 |
Spindle motor starts on power-up |
closed | on |
| Spindle motor starts on command only | open | off |
| Note: Setting CNH11/jumper 6 to "open" will inhibit user settings. | ||
| CONNECTIONS | |
|---|---|
| Purpose | Location |
| External operator panel connector | CN1 |
| External operator panel connector | CN5 |
| Spindle synch connector | CN7 |
| Previous | Table of Contents | Next |